(Double sheathed shielded) High flexibility and bending resistance dragging chain cable
Product Application
Widely used in signal and control applications for automated CNC machining centers, servo motors or servo encoders and other drag chain systems. Copper wire shielding that meets EMC requirements to prevent electromagnetic interference. It can also be used for data transmission, measurement, feedback, encoder, rotary transformer, tachometer, signal and system applications in dry and humid indoor and outdoor environments, as well as in fields such as cranes and conveying facilities, as well as automated production processes.
Oil resistance according to DIN EN 60811-404 4 hours+100C
UV ozone and weather resistance in accordance with EN 50396 and HD 605 S2
Resistant to coolant, microorganisms, and weak acids
Features
Compliant with RoHS
Complies with UL and CUL standards and complies with 2014/35/EU Guideline ("Low Voltage Directive") CE
Product structure
Conductor material: bare copper
Conductor grade according to DIN VDE 0295 Class 6 conductor or. IEC 60228 Class 6 conductor
Core wire insulation PVC-J-105-003 (2105-LF)
Core wire identification<0.5 mm ²: 5-core and below use color separation, in accordance with n. DIN 47100, multi-core cables with 5-core and above use color separation of core wires, with white ink dots for differentiation, ≥ 0.5 mm ²: 5-core and below use color separation, including yellow/green wire, in accordance with n. DIN 47100. Multicore cables with 5-core and above use black core wire, with white ink numbering for differentiation (customized according to special requirements)
Power cable: black sheath, white lettering U/L1: V/L2: W/L3: GN/PE
Cable core wire<10: The core wire is layered and twisted with short pitch
Core wire>11: The core wire is twisted twice
(PVC filling material) Inner sheath DQPVC-H-90-003 (9039-LF)
Shielding tinned copper wire woven shielding density 280%
The outer sheath DQPVC-H-90-003 (9039-LF) has low wear, anti-cutting, and low adhesion. The sheath color is black (RAL 9005); Grey (RAL 7001): Orange (RAL 2004): Green (RAL 6018)
Technical parameter
Rated voltage 25 and above: 0.6/1KV: 0.75 to 16: 300/500V; 0.5 and below 300/300V
Test voltage 3500V: 2000V: 1500V
Conductor resistance+20 ° C according to DIN VDE 0295 Class 6 conductor or IEC 60228 Class 6 conductor
Fixed minimum bending radius of 4 x d
Minimum bending radius movement 7.5 x d
Movement speed self-supporting: max.8 m/s, sliding: max.5 m/s
Wire length self-supporting/sliding max.400 m
Acceleration max.100 m/s2
Bending cycle<35 times/min Lifetime 8 million times
Fixed minimum/maximum operating temperature -40C/+90C (UL: 90C) Moving minimum/maximum operating temperature -25 C/+90C (UL: 90C
Flame retardant grade to comply with IEC 60332-1-2: UL/UL ET1, ET2
Product Application
Widely used in signal and control applications for automated CNC machining centers, servo motors or servo encoders and other drag chain systems. Copper wire shielding that meets EMC requirements to prevent electromagnetic interference. It can also be used for data transmission, measurement, feedback, encoder, rotary transformer, tachometer, signal and system applications in dry and humid indoor and outdoor environments, as well as in fields such as cranes and conveying facilities, as well as automated production processes.
Oil resistance according to DIN EN 60811-404 4 hours+100C
UV ozone and weather resistance in accordance with EN 50396 and HD 605 S2
Resistant to coolant, microorganisms, and weak acids
Features
Compliant with RoHS
Complies with UL and CUL standards and complies with 2014/35/EU Guideline ("Low Voltage Directive") CE
Product structure
Conductor material: bare copper
Conductor grade according to DIN VDE 0295 Class 6 conductor or. IEC 60228 Class 6 conductor
Core wire insulation PVC-J-105-003 (2105-LF)
Core wire identification<0.5 mm ²: 5-core and below use color separation, in accordance with n. DIN 47100, multi-core cables with 5-core and above use color separation of core wires, with white ink dots for differentiation, ≥ 0.5 mm ²: 5-core and below use color separation, including yellow/green wire, in accordance with n. DIN 47100. Multicore cables with 5-core and above use black core wire, with white ink numbering for differentiation (customized according to special requirements)
Power cable: black sheath, white lettering U/L1: V/L2: W/L3: GN/PE
Cable core wire<10: The core wire is layered and twisted with short pitch
Core wire>11: The core wire is twisted twice
(PVC filling material) Inner sheath DQPVC-H-90-003 (9039-LF)
Shielding tinned copper wire woven shielding density 280%
The outer sheath DQPVC-H-90-003 (9039-LF) has low wear, anti-cutting, and low adhesion. The sheath color is black (RAL 9005); Grey (RAL 7001): Orange (RAL 2004): Green (RAL 6018)
Technical parameter
Rated voltage 25 and above: 0.6/1KV: 0.75 to 16: 300/500V; 0.5 and below 300/300V
Test voltage 3500V: 2000V: 1500V
Conductor resistance+20 ° C according to DIN VDE 0295 Class 6 conductor or IEC 60228 Class 6 conductor
Fixed minimum bending radius of 4 x d
Minimum bending radius movement 7.5 x d
Movement speed self-supporting: max.8 m/s, sliding: max.5 m/s
Wire length self-supporting/sliding max.400 m
Acceleration max.100 m/s2
Bending cycle<35 times/min Lifetime 8 million times
Fixed minimum/maximum operating temperature -40C/+90C (UL: 90C) Moving minimum/maximum operating temperature -25 C/+90C (UL: 90C
Flame retardant grade to comply with IEC 60332-1-2: UL/UL ET1, ET2